CABO INDULINK AL (20/35 kV)

ReferênciaCondutorIsolaçãoNúmero de condutoresCoberturaPeso Total (kg/km)
Seção nominal (mm²)Diâmetro nominal (mm)Espessura nominal (mm)Diâmetro nominal (mm)Espessura nominal (mm)Diâmetro nominal (mm)
1352.01.016508,38,827,111,833,31053
1352.03.016508,38,827,133,172,14573
1352.01.017709,98,828,711,935,11188
1352.03.017709,98,828,733,276,25173
1352.01.0189511,88,830,612,037,21350
1352.03.0189511,88,830,633,480,75858
1352.01.01912013,28,832,012,038,61472
1352.03.01912013,28,832,033,583,96400
1352.01.02015014,88,833,612,140,41626
1352.03.02015014,88,833,633,688,07094
1352.01.02118516,38,835,112,141,91786
1352.03.02118516,38,835,133,791,47777
1352.01.02224018,58,837,312,244,32046
1352.03.02224018,58,837,333,996,68837
1352.01.02330020,58,839,312,346,52307
1352.03.02330020,58,839,334,11019891
1352.01.02440023,38,842,112,449,52672
1352.03.02440023,38,842,134,310811372
1352.01.02550026,28,845,012,552,63107
1352.03.02550026,28,845,034,511413104

Description



Print information


Certificates

All information

Construction
Applications
Packaging
Specifications
Construction

1. Conductor: Bare aluminum, alloy 1350, circular compacted stranded (Class 2).

2. Conductor shielding: Semiconductor thermosetting compound

3. Insulation: XLPE 90 °C cross-linked polyethylene thermosetting compound.

4. Insulation Shield: Layer of semiconductor thermosetting compound that is easy to remove when cold.

5. Metal Shield: Bare copper wire.

6. Separator: Non-hygroscopic polyester tape, applied in a helix covering 100% of the cable.

7. Cover: Polyvinyl chloride compound PVC ST2.

Cables with 3 conductors, vein identification by means of white, blue and red ribbons

Applications

INDULINK CABLES are used in input and/or distribution circuits in residential or industrial buildings, substations, etc. They can be installed outdoors, in conduits, ducts, trays or directly underground.

Packaging

They are usually packed on wooden reels.

Specifications

ABNT NBR 7287 Power cables with extruded cross-linked polyethylene (XLPE) insulation for voltages from 1 kV to 35 kV – Performance requirements


informações e Tabela


Certificados

CABO INDULINK AL (20/35 kV)

ReferênciaCondutorIsolaçãoNúmero de condutoresCoberturaPeso Total (kg/km)
Seção nominal (mm²)Diâmetro nominal (mm)Espessura nominal (mm)Diâmetro nominal (mm)Espessura nominal (mm)Diâmetro nominal (mm)
1352.01.016508,38,827,111,833,31053
1352.03.016508,38,827,133,172,14573
1352.01.017709,98,828,711,935,11188
1352.03.017709,98,828,733,276,25173
1352.01.0189511,88,830,612,037,21350
1352.03.0189511,88,830,633,480,75858
1352.01.01912013,28,832,012,038,61472
1352.03.01912013,28,832,033,583,96400
1352.01.02015014,88,833,612,140,41626
1352.03.02015014,88,833,633,688,07094
1352.01.02118516,38,835,112,141,91786
1352.03.02118516,38,835,133,791,47777
1352.01.02224018,58,837,312,244,32046
1352.03.02224018,58,837,333,996,68837
1352.01.02330020,58,839,312,346,52307
1352.03.02330020,58,839,334,11019891
1352.01.02440023,38,842,112,449,52672
1352.03.02440023,38,842,134,310811372
1352.01.02550026,28,845,012,552,63107
1352.03.02550026,28,845,034,511413104

Solicite o seu orçamento​