CONTACT US | +55 (11) 4634 - 9000

Search
Close this search box.

CONTACT US
+55 (11) 4634 - 9000

INDUGREX Medium Voltage Alumina Cable – AL / SCI TR 25kV – 35kV

The Aluminum Medium Voltage Cable INDUGREX – AL / SCI TR 25kV – 35kV is a cable used in medium voltage electrical installations, with nominal voltages between 25kV and 35kV. It consists of aluminum conductors and insulation in cross-linked thermosetting compound (XLPE), with a halogen-free extruded semiconductor layer (HEPR) and thermoplastic polyolefin (HDPE) cover.

All information

CABO INDUGREX – AL / SCI TR 25kV

ReferênciaSeção Nominal (mm²)Diâmetro Nominal do Condutor (mm)Cobertura Espessura Nominal da Cobertura (mm)Diâmetro Externo Nominal(mm)Peso Líquido Nominal (kg/km)
1446.01.015357,104,016,3256
1446.01.016508,304,017,5305
1446.01.017709,904,019,1386
1446.01.0189511,74,020,9481
1446.01.01912013,24,022,4568
1446.01.02015014,54,023,7658
1446.01.02118516,34,025,5787
1446.01.02224018,54,027,7969
1446.01.02330020,74,029,71156

CABO INDUGREX – AL / SCI TR 35kV

ReferênciaSeção Nominal (mm²)Diâmetro Nominal do Condutor (mm)Cobertura Espessura Nominal da Cobertura (mm)Cobertura Diâmetro Externo Nominal (mm)Peso Líquido Nominal (kg/km)
1447.01.017709,907,626,3625
1447.01.0189511,77,628,1738
1447.01.01912013,27,629,6841
1447.01.02015014,57,630,9945
1447.01.02118516,37,632,71093
1447.01.02224018,57,634,91298
1447.01.02330020,57,636,91506

Description



Print information


Certificates

All information

Construction
Aplicações
Acondicionamento
Especificações
Construction

1. Conductor: Bare aluminum, 1350, stranded with compact circular section class 2 blocked against water penetration

2. Conductor shielding: Semiconductor thermosetting compound – 90°C.

2B. Cover: Cross-linked polyethylene (XLPE) thermosetting compound – 90°C, resistant to electrical sparking.

INDUGREX -TR CABLES are normally supplied in gray

Aplicações

Used for overhead power distribution at voltages of 25kV and 35kV between phases, where installation space is limited. Considered to be a non-insulated conductor, it has a covering that is resistant to short circuits and discharges caused by contact with tree branches and humidity (resistant to electrical sparking). It can also be used with other cables in a configuration defined by spacers occupying minimal space (compact network), which is very useful in congested areas.

Acondicionamento

They are usually packed in wooden reels

Especificações

INDUGREX-AL TR CABLES meet or exceed all applicable specifications, especially those dictated by the standards:
NBR 11873 – XLPE-covered aerial cables for use in wooded areas with voltages of 25kV and 35kV.
ASTM D 21323 – Standard test method for dust – and – fog tracking and erosion resistance of electrical insulating materials.


informações e Tabela


Certificados

CABO INDUGREX – AL / SCI TR 25kV

ReferênciaSeção Nominal (mm²)Diâmetro Nominal do Condutor (mm)Cobertura Espessura Nominal da Cobertura (mm)Diâmetro Externo Nominal(mm)Peso Líquido Nominal (kg/km)
1446.01.015357,104,016,3256
1446.01.016508,304,017,5305
1446.01.017709,904,019,1386
1446.01.0189511,74,020,9481
1446.01.01912013,24,022,4568
1446.01.02015014,54,023,7658
1446.01.02118516,34,025,5787
1446.01.02224018,54,027,7969
1446.01.02330020,74,029,71156

CABO INDUGREX – AL / SCI TR 35kV

ReferênciaSeção Nominal (mm²)Diâmetro Nominal do Condutor (mm)Cobertura Espessura Nominal da Cobertura (mm)Cobertura Diâmetro Externo Nominal (mm)Peso Líquido Nominal (kg/km)
1447.01.017709,907,626,3625
1447.01.0189511,77,628,1738
1447.01.01912013,27,629,6841
1447.01.02015014,57,630,9945
1447.01.02118516,37,632,71093
1447.01.02224018,57,634,91298
1447.01.02330020,57,636,91506

Solicite o seu orçamento​