Control Cable (HEPR/PVC) 1000V Shielded with Polyester + Drain Alumina Tape

Control cable (HEPR/PVC) 1000V shielded with polyester aluminum tape + drain is a cable designed for transmitting control signals in medium-voltage electrical systems. HEPR stands for Ethylene Propylene Rubber, a type of rubber used as an insulator, while PVC is polyvinyl chloride used for sheathing.

All information

CABO DE CONTROLE (HEPR/PVC) 1000V BL AL POLIÉSTER + DRENO

SEÇÃO NOMINAL: 1,5 MM²

Referência EPR/PVCNúmero de CondutoresEspessura Nominal de Cobertura (mm)Diâmetro Externo Nominal (mm)Peso Líquido Nominal (kg/km) EPR/PVC
2854.02.00821,48,8399,1
2854.03.00831,49,29110
2854.04.00841,410,0135
2854.05.00851,410,9162
2854.06.00861,411,7188
2854.07.00871,411,7194
2854.09.00891,413,5250
2854.12.008121,415,0302
2854.15.008151,416,6378
2854.20.008201,418,4478
2854.25.008251,420,4557

SEÇÃO NOMINAL: 2,5 MM²

Referência EPR/PVCNúmero de CondutoresEspessura Nominal de Cobertura (mm)Diâmetro Externo Nominal (mm)Peso Líquido Nominal (kg/km) EPR/PVC
2854.02.00921,49,7129
2854.03.00931,410,2144
2854.04.00941,411,1179
2854.05.00951,412,1216
2854.06.00961,413,0255
2854.07.00971,413,0267
2854.09.00991,415,1347
2854.12.009121,411,9424
2854.15.009151,418,7535
2854.20.009201,420,7681
2854.25.009251,423,0803

Description



Print information


Certificates

All information

Construction
Applications
Packaging
Specifications
Construction

1. Conductor: Bare electrolytic copper, soft temper, flexible stranding.

2. Insulation: Extruded thermosetting compound of ethylene-propylene rubber (HEPR) 90 ºC.

3. Assembly: The veins (insulated conductors) are twisted together in concentric crowns to form the core of the cable.

4.Separator: Banding with polyester tape, applied in an overlapping helix, over the meeting of the strands.

5.Shielding: Aluminum/polyester tape applied helically with the aluminized side in electrical contact with the 0.50 mm² tinned cable drain conductor.

6.Cover: Braids of tinned copper wire.

7.Cover: Extruded layer of flame-retardant polyvinyl chloride (PVC)-based compound in black.

Numbered black veins.

Applications

In control, signaling, remote control and power supply circuits in fixed installations with a voltage rating of up to 1000V. For installations requiring protection against interference, noise and magnetic fields.

Packaging

They are usually packed in wooden reels.

Specifications

NBR-7290 – Control cables with extruded XLPE or HEPR insulation for voltages up to 1 kV.


informações e Tabela


Certificados

CABO DE CONTROLE (HEPR/PVC) 1000V BL AL POLIÉSTER + DRENO

SEÇÃO NOMINAL: 1,5 MM²

Referência EPR/PVCNúmero de CondutoresEspessura Nominal de Cobertura (mm)Diâmetro Externo Nominal (mm)Peso Líquido Nominal (kg/km) EPR/PVC
2854.02.00821,48,8399,1
2854.03.00831,49,29110
2854.04.00841,410,0135
2854.05.00851,410,9162
2854.06.00861,411,7188
2854.07.00871,411,7194
2854.09.00891,413,5250
2854.12.008121,415,0302
2854.15.008151,416,6378
2854.20.008201,418,4478
2854.25.008251,420,4557

SEÇÃO NOMINAL: 2,5 MM²

Referência EPR/PVCNúmero de CondutoresEspessura Nominal de Cobertura (mm)Diâmetro Externo Nominal (mm)Peso Líquido Nominal (kg/km) EPR/PVC
2854.02.00921,49,7129
2854.03.00931,410,2144
2854.04.00941,411,1179
2854.05.00951,412,1216
2854.06.00961,413,0255
2854.07.00971,413,0267
2854.09.00991,415,1347
2854.12.009121,411,9424
2854.15.009151,418,7535
2854.20.009201,420,7681
2854.25.009251,423,0803

Solicite o seu orçamento​